I-Online UPS Power Regulation Backup 6K-20kVA ene-Pfc Over 0.99
Incazelo Yomkhiqizo
Ayikho iBreak Online UPS Power 6k-20kVA High Frequency Tower UPS ene-0.99 Power Factor
Izinzuzo zesistimu yethu yamandla angaphazamiseki (i-UPS).
1.Umugqa omuhle wokuvumelana nezimo zenethiwekhi Ububanzi bevoltheji yokufaka ebanzi:110-330V Ibanga lefrikhwensi yokufaka ebanzi:40~70Hz
2.Izicaciso zokusebenza ezithuthukisiwe
Isici samandla okukhiphayo esingu-1.0 ngokuzithandela, Ukusebenza kahle kwamandla okuphezulu ngaphezu kwama-94%, Okokufaka kwe-THDI kungaphansi kuka-5%
I-THDV ephumayo ingaphansi kuka-4% umthwalo ongaqondile
3.Izindlela zokuqapha nokuphatha ezihlakaniphile
4.Umthwalo oqinile kanye nomthamo wokulayisha ngokweqile
Imininingwane:
Imodeli | 1K | 2K | 3K | 6K | 10K |
Isigaba | Isigaba esisodwa esinomhlabathi | ||||
Okokufaka | |||||
Linganisa umthamo | 1KVA/900W | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/6KW | 10KVA/10KW |
Linganisa i-voltage | 110/115/120/127VAC noma 220/230/240VAC | 220/230/240VAC | |||
Vula ububanzi be-voltage | 55-150VAC noma 110-300VAC ≤50% umthwalo | 110-300VAC ≤50% umthwalo | |||
80-150VAC noma 160-300VAC ≤100% umthwalo | 176-300VAC ≤100% umthwalo | ||||
Ibanga lemvamisa | 40 ~ 70Hz | 46~54Hz noma 56~64Hz | |||
Isici samandla | ≥0.99 100% umthwalo | ||||
I-THDI | ≤5% | ≤4% | |||
Okukhiphayo | |||||
Linganisa i-voltage | 110/115/120/127VAC noma 220/230/240VAC | 220/230/240VAC | |||
Ukulawulwa kwamandla kagesi | ±1% | ||||
Imvamisa yemodi yomugqa | 47~53Hz noma 57~63Hz | 46~54Hz noma 56~64Hz | |||
Imvamisa yemodi ye-Bat | 50Hz noma 60Hz ±0.1Hz | ||||
I-voltage ye-harmonic | ≤2% R umthwalo | ≤1% R umthwalo | |||
≤4% umthwalo we-RCD | ≤4% umthwalo we-RCD | ||||
Isabelo se-Crest | 3:01 | ||||
Ukudluliswa kwe-Line-Bat | 0ms | ||||
Ukudluliswa kwe-INV-Bypass | ≤4ms | 0ms | |||
Ukulayisha ngokweqile | 100%±5%130%±5%:1s;( dlulisela ku-bypass ne-alamu) Qaphela: Imodi yomugqa engu-6-10K | ||||
Ukusebenza kahle | |||||
Imodi yomugqa | > 90% | > 91% | > 91% | > 94% | > 94% |
Imodi ye-Bat | > 89% | > 89% | > 90% | > 91% | > 91% |
Ibhethri | |||||
Inombolo | 3 | 6 | 8 | 16 noma 20 (20 kuphela ubude) | |
I-voltage yeshaja | 41.0VDC | 82.1VDC | 109.6VDC | 218.4VDC/273VDC | |
Shaja okwamanje (isitendi) | 1.5A | 1.2A | 1A | ||
Shaja okwamanje(inde) | 1A/2A/4A/6A/8A(iyalungiseka) | 4.0A | |||
Usayizi(ubude*ububanzi*ubude)kanye nesisindo | |||||
I-Stand UPS(mm) | 397*145*220 | 421*190*318 | 421*190*318 | 369*190*688/ | 442*190*688 |
Isisindo(kg) | 12 | 22.5 | 32.2 | 54 | 66 |
I-UPS yesikhathi eside(mm) | 397*145*220 | 421*190*318 | 369*190*318 | 442*190*318 | |
Isisindo(kg) | 6.3 | 10.5 | 11.7 | 13 | 16 |
Imvelo | |||||
Izinga lokushisa lomsebenzi | 0ºC~40ºC | ||||
Umswakama womsebenzi | 20%~95% | ||||
Umsindo ozwakalayo | ≤50dB | ≤55dB | ≤58dB | ||
Ukuxhumana | I-RS-232/USB/SNMP ikhadi elilungisekayo |